In image-guided radiotherapy (IGRT) based on Cone Beam CT (CBCT), daily CBCT imaging procedures correct the set-up errors of patients, but also increase additional dose to patients' normal tissues. Minimizing imaging views of CBCT is an direct and effective way to reduce extra radiation exopsure. Our goal is to establish a novel high-quality CBCT reconstruction system with limited CBCT imaging viewes at a high reconstruction speed based on CPU+MultiGPU configuration avilable for image-guided radiotherapy clincial practices..We will complete two tasks in our project. One is to further establish a high-quality recosntruction algorithm with limited number of CBCT imaging views to solve the CBCT reconstruction model mathmatically. The second task is to construct a CPU+multiGPU heterogeneous programming mode to accelerate the reconstruction process and establish an IGRT CBCT system suitable for clinical application..Our inital experimental simulation shows that our system is promising to reduce the CBCT radiation dose to 30% in clinical IGRT practice and significantly reduce the radiation hazards produced by IGRT.
以CBCT为核心的图像引导放疗中,放疗患者多次行CBCT扫描以实现放疗精确摆位,但同时引起了额外的辐射剂量,减少CBCT扫描帧数是降低CBCT辐射剂量直接有效的途径。仅利用部分投影帧数据进行CBCT高质量重建,并构建CPU+多GPU构架将系统重建速度提高到临床可接受水平,是本项目的核心问题。. 本项目将基于压缩感知理论和字典学习算法,将少数据CBCT重建问题转化为最优化问题求解,充分利用同一放疗部位的先验CBCT图像,构建具有结构、特征、精度等先验信息的双精度字典,通过迭代算法中高低精度字典的替换迅速提高CBCT图像重建质量。同时,搭建CPU+多GPU异构并行编程模式加速重建过程,构造临床适用的图像引导放疗系统。. 模拟实验表明,在保证CBCT图像重建质量的前提下,本系统能够将CBCT扫描剂量降低至全扫描情况下的30%,显著减少患者的CBCT扫描辐射危害。
以锥形束CT(Cone Beam CT, CBCT)为核心的图像引导放疗中,放疗患者多次行CBCT扫描以实现放疗精确摆位,但同时引起了额外的辐射剂量。仅利用部分投影帧数据进行CBCT高质量重建可大幅降低患者受照剂量,但部分投影CBCT高质量重建耗时长、重建质量尚不能满足临床需求。建立部分投影高质量CBCT重建系统并将系统重建速度提高到临床可接受水平,是本项目的目标。..本项目研究并建立了基于压缩感知理论和字典学习的部分投影高质量CBCT重建算法( SART-DDL)并对其重建图像质量进行了临床效果评价,探究了CPU+多GPU并行编程模式加速重建过程,探索了可编程门阵列(FPGA)加速重建过程;研究并建立了基于卷积神经网络的部分投影CBCT超分辨图像重建算法(Network-LDR),并对其重建图像质量进行了客观指标评价。..在头颈部CBCT扫描82%的降采样率下,SART-DDL比传统迭代算法 SART-TV在定量指标峰值信噪比(Peak Signal to Noise Ratio, PSNR)高2 dB,结构相似度(Structural Similarity Index Measure, SSIM) 高1%,均有统计学差异;SART-DDL重建结果图像主观评价质量与全采样传统FDK重建结果图像没有统计学差异,配准效果能够达到毫米级,满足放射治疗几何精度保形性要求。Network-LDR与传统FDK重建算法相比,在头颈部CBCT扫描12.5%、6.25%、3.125%、1.5625%的降采样率下,Network-LDR比FDK算法平均PSNR值约高25 dB、15 dB、16 dB、12 dB,平均SSIM值约高12%、18%、81%、68%;以上对比均有统计学差异。对256*256*88 的CBCT重建目标图像,SART-DDL在8GPU+CPU的框架下重建速度约2小时,在FPGA框架下约1小时,无法满足临床实时重建的速度要求;Network-LDR在2GPU+CPU的框架下,重建速度约1.86秒,可满足临床实时重建的速度要求。
{{i.achievement_title}}
数据更新时间:2023-05-31
内点最大化与冗余点控制的小型无人机遥感图像配准
平行图像:图像生成的一个新型理论框架
基于贝叶斯统计模型的金属缺陷电磁成像方法研究
能谱联合迭代重建在重度肝硬化双低扫描中的应用价值
基于近似L_0范数的电容层析成像敏感场优化算法
先验图像引导的低剂量X射线CT图像噪声抑制研究
光学CT图像引导的眼内肿瘤自适应放疗研究
基于注意力生成对抗网络的低剂量CT图像重建方法研究
面向肺癌筛查的低剂量CT成像: 基于投影筛选与CT图像库学习的精准重建